task-13: elmyra_raw streams at 100Hz; force produces no deflection
This commit is contained in:
parent
f2213ce194
commit
db5220633d
1 changed files with 64 additions and 0 deletions
|
|
@ -316,3 +316,67 @@ silence.
|
|||
So the remaining question is not "is the SUID served" (it is) but **who
|
||||
configures IRQ 125**. Downstream that is vendor DT/driver work. Start there,
|
||||
not at the client.
|
||||
|
||||
## Update 2026-07-27 — the right sensor, streaming at 100 Hz, force does nothing
|
||||
|
||||
### Corrections to the entry above
|
||||
|
||||
`sns_touch_gesture` is **not** Active Edge. `PAF/touch.md:127` says it is the
|
||||
FTS double-tap nanoapp on the SLPI's i2c bus 5, and the registry agrees
|
||||
(slave 0x49, bus 5, irq 125 = the touch controller). The `irq_skip_pin_config`
|
||||
lead in the previous entry belongs to double-tap-to-wake, not to squeeze.
|
||||
|
||||
**Active Edge is `elmyra_raw`** — the strain gauge array on the MAX11261.
|
||||
Resolves to SUID `15717249801838747009 / 6291402259395006624`.
|
||||
|
||||
### Two libssc bugs, both patched (pkgs/libssc-souveraine)
|
||||
|
||||
1. **Single-output sensors aborted the caller.** `sensor_open()` had
|
||||
`g_assert_not_reached()` for any stream type other than continuous(0) or
|
||||
on-change(1). Fixed: type 2 defined, opened like on-change, and the assert
|
||||
replaced by a returned error — a library must not abort its caller over a
|
||||
value it read off the device.
|
||||
2. **Sample rate was the first advertised, not the fastest.** libssc took
|
||||
`v[0]` ("Only a single sample rate is supported for now"), giving **1 Hz**
|
||||
on a sensor the factory capture shows running at ~115 Hz. A squeeze lasting
|
||||
half a second was invisible. Now takes the maximum: **confirmed 100 Hz on
|
||||
device.**
|
||||
|
||||
Both belong upstream (codeberg.org/DylanVanAssche/libssc); neither is
|
||||
blueline-specific.
|
||||
|
||||
### The producer works
|
||||
|
||||
`pkgs/blueline-edge-sense` opens `elmyra_raw`, decodes six floats per sample,
|
||||
loads this unit's factory `touch_2_sensitivity` values
|
||||
(0.240 0.295 0.176 0.359 0.329 0.342), holds a rolling baseline and computes
|
||||
summed normalised deflection. Live baseline on device:
|
||||
`-79445 -104899 322598 236201 139847 53762` — six real gauges in the ±100k
|
||||
range the factory sweep shows.
|
||||
|
||||
The threshold model comes from Google's own calibration sweep
|
||||
(`persist/sensors/edgesense_roller_cal/0_raw/sensor_data.csv`), which captures
|
||||
the gauges at a known 10 N and 20 N: the loaded bank moves 400–2000 counts per
|
||||
10 N step.
|
||||
|
||||
### Where it stops
|
||||
|
||||
**Squeezing produces no signal.** 399 samples across 35 s of deliberate hard
|
||||
squeezes: median deflection 49, p99 98, **max 127** — indistinguishable from
|
||||
the resting noise floor. The ADC is alive and the values move; they just do not
|
||||
move with applied force.
|
||||
|
||||
So the gauges are being read but not *excited*. Things to look at next, in
|
||||
order:
|
||||
|
||||
- `b1c1_max11261_no_pullup.json` carries `reset_gpio`, `haptic_gpio`,
|
||||
`gpo_delay`, `mux_delay`, `gain`, `lp_mode`. Nothing configures these.
|
||||
- `sensor_def_qcomdev.conf` cfg 6 names SSC-side pins for this sensor:
|
||||
`gpio1 = 0x108` (data ready), `gpio2 = 0x100` (reset). Neither is touched.
|
||||
- `results.csv` from the factory run records `afe_gain 2.0` — the analog front
|
||||
end has a gain setting that presumably must be programmed.
|
||||
- PM8998 GPIO 2 is held high (`blueline-edge-sense-power`, verified active
|
||||
after reboot). That is the rail the vendor script raises, so it is necessary
|
||||
but evidently not sufficient.
|
||||
|
||||
The remaining work is bridge excitation / AFE configuration, not the client.
|
||||
|
|
|
|||