lock: surface charge rate, and stop counting down while plugged in
UPower's ChargeType (fork, read off the charger) reaches the lock line as fast/slow charging. Discharging with the cable in is the charger resting between top-ups, not a drain — it now reads Charged/Plugged in.
This commit is contained in:
parent
7475fae505
commit
2b69957f18
4 changed files with 152 additions and 1 deletions
|
|
@ -68,11 +68,23 @@ Item {
|
|||
case UPowerDeviceState.FullyCharged:
|
||||
return "Full " + pct + "%";
|
||||
case UPowerDeviceState.Charging:
|
||||
// ChargeRate.label is "Charging" unless the charger
|
||||
// is doing something worth naming — fast, trickle,
|
||||
// long-life. A charger that has quietly dropped to
|
||||
// trickle used to look exactly like one that hadn't.
|
||||
// Right after a driver rebind the pack can briefly
|
||||
// report 0% while charging. Drop the number rather
|
||||
// than lie.
|
||||
return pct > 0 ? "Charging " + pct + "%" : "Charging";
|
||||
return pct > 0 ? ChargeRate.label + " " + pct + "%"
|
||||
: ChargeRate.label;
|
||||
case UPowerDeviceState.Discharging:
|
||||
// Discharging with the cable still in is the charger
|
||||
// resting between top-ups, not the battery draining.
|
||||
// Saying "Battery 94%" there — and watching it count
|
||||
// down while plugged in — reads as a broken charger.
|
||||
if (ChargeRate.pluggedNotCharging)
|
||||
return pct >= 95 ? "Charged " + pct + "%"
|
||||
: "Plugged in " + pct + "%";
|
||||
return "Battery " + pct + "%";
|
||||
default:
|
||||
// Unknown / Empty / Pending* — show the number
|
||||
|
|
|
|||
Loading…